40 research outputs found

    Fluorescence based detection of bioaerosols to improve emissions characterization from environmental sources

    Get PDF
    Bioaerosols are ubiquitous in ambient air but there have been increasing concerns about their human exposure and to health impact due to ever increasing environmental emissions from sources such as biowaste and intensive agriculture facilities (Borlée et al. 2015). However, the knowledge on their risk of exposure to the public is limited mainly due to a lack of emission characterisation, in part due to the limitation of conventional methods for the detection and characterisation of ambient bioaerosols. Among emerging techniques, fluorescence spectroscopy has shown promise in detecting and broadly classifying bioaerosols (Pan et al. 2015). This paper provides the preliminary results of a study that aims to demonstrate the potential of a fluorescence based bioaerosol sensor unit to detect and quantify these in real time with a view to developing and advancing bioaerosol exposure assessment methodologies to various environmental sources

    Rotating biological contactors for wastewater treatment - A review

    Get PDF
    Rotating biological contactors (RBCs) for wastewater treatment began in the 1970s. Removal of organic matter has been targeted within organic loading rates of up to 120 g m−2 d−1 with an optimum at around 15 g m−2 d−1 for combined BOD and ammonia removal. Full nitrification is achievable under appropriate process conditions with oxidation rates of up to 6 g m−2 d−1 reported for municipal wastewater. The RBC process has been adapted for denitrification with reported removal rates of up to 14 g m−2 d−1 with nitrogen rich wastewaters. Different media types can be used to improve organic/nitrogen loading rates through selecting for different bacterial groups. The RBC has been applied with only limited success for enhanced biological phosphorus removal and attained up to 70% total phosphorus removal. Compared to other biofilm processes, RBCs had 35% lower energy costs than trickling filters but higher demand than wetland systems. However, the land footprint for the same treatment is lower than these alternatives. The RBC process has been used for removal of priority pollutants such as pharmaceuticals and personal care products. The RBC system has been shown to eliminate 99% of faecal coliforms and the majority of other wastewater pathogens. Novel RBC reactors include systems for energy generation such as algae, methane production and microbial fuel cells for direct current generation. Issues such as scale up remain challenging for the future application of RBC technology and topics such as phosphorus removal and denitrification still require further research. High volumetric removal rate, solids retention, low footprint, hydraulic residence times are characteristics of RBCs. The RBC is therefore an ideal candidate for hybrid processes for upgrading works maximising efficiency of existing infrastructure and minimising energy consumption for nutrient removal. This review will provide a link between disciplines and discuss recent developments in RBC research and comparison of recent process designs are provided (Section 2). The microbial features of the RBC biofilm are highlighted (Section 3) and topics such as biological nitrogen removal and priority pollutant remediation are discussed (Sections 4 and 5). Developments in kinetics and modelling are highlighted (Section 6) and future research themes are mentioned

    Long-term impact of sewage sludge application on soil microbial biomass: An evaluation using meta-analysis

    Get PDF
    The Long-Term Sludge Experiments (LTSE) began in 1994 as part of continuing research into the effects of sludge-borne heavy metals on soil fertility. The long-term effects of Zn, Cu, and Cd on soil microbial biomass carbon (Cmic) were monitored for 8 years (1997-2005) in sludge amended soils at nine UK field sites. To assess the statutory limits set by the UK Sludge (Use in Agriculture) Regulations the experimental data has been reviewed using the statistical methods of meta-analysis. Previous LTSE studies have focused predominantly on statistical significance rather than effect size, whereas meta-analysis focuses on the magnitude and direction of an effect, i.e. the practical significance, rather than its statistical significance. The results presented here show that significant decreases in Cmic have occurred in soils where the total concentrations of Zn and Cu fall below the current UK statutory limits. For soils receiving sewage sludge predominantly contaminated with Zn, decreases of approximately 7–11% were observed at concentrations below the UK statutory limit. The effect of Zn appeared to increase over time, with increasingly greater decreases in Cmic observed over a period of 8 years. This may be due to an interactive effect between Zn and confounding Cu contamination which has augmented the bioavailability of these metals over time. Similar decreases (7–12%) in Cmic were observed in soils receiving sewage sludge predominantly contaminated with Cu; however, Cmic appeared to show of recovery after a period of 6 years. Application of sewage sludge predominantly contaminated with Cd appeared to have no effect on Cmic at concentrations below the current UK statutory limit

    Estimation of particulate matter and gaseous concentrations using low-cost sensors from broiler houses

    Get PDF
    Particulate and gaseous emissions from intensive poultry facilities are major public and environmental health concern. The present study was aimed at exploratively monitoring particulate matter (PM) and gaseous concentrations in controlled-environment facilities using low-cost sensors in Lahore, Pakistan. The indoors and outdoors of 18 broiler houses, grouped into three categories based on the age of birds: group I (1–20 days), group II (21–30 days) and group III (31–40 days), were examined. Low-cost sensors Dylos 1700 and Aeroqual 500 series with different gas sensor heads were used to monitor PM and different gases such as nitrogen dioxide (NO2), hydrogen sulphide (H2S), carbon dioxide (CO2) and methane (CH4), respectively. Overall, the mean PM and gaseous concentrations increased with the age and activity of birds as compared with the non-activity time of birds. Statistically significant differences were observed in all measured parameters among the groups. The negative correlation between indoor and outdoor environments for PM and gas concentrations at some broiler houses demonstrates the contribution of additional sources to emissions in outdoor environments. The findings contribute to our knowledge of temporal characteristics of particulate and gaseous concentrations from poultry facilities particularly in Pakistan and generally to the capability of using low-cost sensors to evaluate emissions from such facilities

    Phosphorus flow analysis for Malawi: Identifying potential sources of renewable phosphorus recovery

    Get PDF
    Population growth and dietary needs changes have exerted pressure on phosphorus (P) reserves, and the future availability of P fertilisers is uncertain. Most Malawian soils have low P and farmers apply P fertilisers to harvest enough food. Scarcity of chemical P fertilisers and rising prices will affect Malawi's food security. To avert the impact of P future uncertainty a P flow analysis (PFA) was conducted to characterise and quantify sources, flows, and sinks of P to determine options for waste minimisation, recovery, and chemical fertiliser use reduction for Malawi. The PFA results highlighted that; there are 35000 Mg of recyclable organic P annually, which is over two times Malawi's annual P fertiliser demand (14000 Mg). Currently, only 16% of the organic P is recycled to agriculture. Chemical P fertiliser represents 66 % of the P fertiliser used for crop production. Manure is the most recycled organic P source (38 % recycled), followed by organic solid waste (6%), and crop residues (5%). Annually, 9000 Mg of P is transferred to faecal matter, but none is recycled. Overall, Malawian soils have a negative P balance of -4000 Mg. Malawi can reduce its dependence on imported chemical P if recycling of organic P source is adopted. However, regulations should be put in place to control the quality of organic fertiliser

    Characterisation of organomineral fertilisers derived from nutrient-enriched biosolids granules

    Get PDF
    Organomineral fertilisers (OMFs) were produced by coating biosolids granules with urea and potash. Two OMF formulations with N : P2O5 : K2O compositions: 10 : 4 : 4 (OMF10) and 15 : 4 : 4 (OMF15) were developed for application in grassland and arable crops. Routine fertiliser analyses were conducted on four batches of OMF and biosolids granules and compared with a sample of urea to determine key physical and chemical properties of the materials which affect handling and spreading, soil behaviour, and fertiliser value. Bulk and particle densities were in the range of 608 to 618 kg m−3, and 1297 to 1357 kg m−3, respectively. Compression tests showed that OMF particles undergo deformation followed by multiple failures without disintegration of the granules when vertical load was applied. Static particle strength was between 1.18 and 4.33 N mm−2 depending on the particle diameter. The use of a model for fertiliser particle distribution studies showed that OMF granules should be between 1.10 and 5.50 mm in diameter with about 80% of the particles in the range of 2.25 to 4.40 mm to enable application at 18 m tramline spacing. This research utilises novel technology to improve the fertiliser value of biosolids, reduce disposal costs, and deliver a range of environmental benefits associated with recycling

    Assessment of respiratory problems in workers associated with intensive poultry facilities in Pakistan

    Get PDF
    Background The poultry industry in Pakistan has flourished since the 1960s; however, there are scarce data regarding the impact of occupational exposure on the pulmonary health of farm workers in terms of years working in the industry. The objective of the present study was to assess the effect of poultry environment on the health of occupationally exposed poultry farmers in countries of warm climatic regions, such as Pakistan. This study will also show the effect of exposure to poultry facilities on the health of poultry farmers in the context of low-income countries with a relatively inadequate occupational exposure risk management. Materials and methods The lung function capacity of 79 poultry workers was measured using a spirometer. Along with spirometry, a structured questionnaire was also administrated to obtain information about age, height, weight, smokers/nonsmokers, years of working experience, and pulmonary health of farm workers. The workers who were directly involved in the care and handling of birds in these intensive facilities were considered and divided into four groups based on their years of working experience: Group I (3-10 months), Group II (1-5 years), Group III (6-10 years), and Group IV (more than 11 years). The forced vital capacity (FVC), forced expiratory volume in one second (FEV1) and the FEV1/FVC ratio were considered to identify lung function abnormalities. Statistical analysis was carried out using independent sample t test, Chi-square test, Pearson's correlation, and linear regression. Results Based on the performed spirometry, 68 (86 %) of workers were found normal and healthy, whereas 11 (14 %) had a mild obstruction. Of the 11 workers with mild obstruction, the highest number with respect to the total was in Group IV (more than 11 years of working experience) followed by Group III and Group II. Most of the workers were found healthy, which seems to be because of the healthy survivor effect. For the independent sample t test, a significant difference was noticed between healthy and nonhealthy farmers, whereas Chi-square test showed a significant association with height, drugs, and working experience. Linear regression that was stratified by respiratory symptoms showed for workers with symptoms, regression models for all spirometric parameters (FVC, FEV1, and FEV1/FVC) have better predictive power or R square value than those of workers without symptoms. Conclusion These findings suggest that lung function capacity was directly related to years of working experience. With increasing number of working years, symptoms of various respiratory problems enhanced in the poultry workers. It should be noted that most of the poultry workers were healthy and young, the rationale being that there is a high turnover rate in this profession. The mobility in this job and our finding of 86% of the healthy workers in the present study also proposed healthy worker survivor effec

    Real time detection and characterisation of bioaerosol emissions from wastewater treatment plants

    Get PDF
    Bioaerosol emissions from wastewater treatment plants may pose adverse health impact on workers and nearby communities. To detect and characterise bioaerosol emissions from wastewater treatment plant (WWTP), a novel real-time bioaerosol sensor, Spectral Intensity Bioaerosol Sensor (SIBS) was employed at a WWTP and a background site. The SIBS records a range of data (size, shape, and fluorescence emission across 16 wavelength bands from 298 to 735 nm for two excitation wavelengths (285 nm and 370 nm)) on single particles in real time. Additionally, excitation-emission matrix (EEM) of wastewater samples obtained by a spectrofluorometer was compared with SIBS spectra from WWTP. The results showed that the average number concentrations of total particles (NT) and fluorescence particles (NF) were both higher at the WWTP (NT = 2.01 cm−3, NF = 1.13 cm−3) than the background site (NT = 1.79 cm−3, NF = 1.01 cm−3). The temporal variation of NF and NT was highly variable at the WWTP and the concentration peaks were consistent with on-site activities. Moreover, the time-resolved number-size distribution of fluorescent particles revealed the predominance of fine scale particles (<1 μm) and the time-series channel by channel number concentrations demonstrated the temporal variability of dominant bio-fluorophores. Furthermore, the overall and size-segregated fluorescence spectra at two sites were multimodal. In particular, the fluorescence intensity increases with increasing particle size in WWTP spectra, which is not present in the background spectra. In addition, the highly resolved SIBS fluorescence spectra were broadly similar to EEM of wastewater. These findings confirmed that the spectrally resolved fluorescence detected by SIBS is capable of providing reliable bio-fluorophores information of bioaerosol emissions generated from wastewater, thus holding the potential for better characterisation of bioaerosols in real time

    An experimental investigation of the combustion performance of human faeces

    Get PDF
    Poor sanitation is one of the major hindrances to the global sustainable development goals. The Reinvent the Toilet Challenge of the Bill and Melinda Gates Foundation is set to develop affordable, next-generation sanitary systems that can ensure safe treatment and wide accessibility without compromise on sustainable use of natural resources and the environment. Energy recovery from human excreta is likely to be a cornerstone of future sustainable sanitary systems. Faeces combustion was investigated using a bench-scale downdraft combustor test rig, alongside with wood biomass and simulant faeces. Parameters such as air flow rate, fuel pellet size, bed height, and fuel ignition mode were varied to establish the combustion operating range of the test rig and the optimum conditions for converting the faecal biomass to energy. The experimental results show that the dry human faeces had a higher energy content (∼25 MJ/kg) than wood biomass. At equivalence ratio between 0.86 and 1.12, the combustion temperature and fuel burn rate ranged from 431 to 558 °C and 1.53 to 2.30 g/min respectively. Preliminary results for the simulant faeces show that a minimum combustion bed temperature of 600 ± 10 °C can handle faeces up to 60 wt.% moisture at optimum air-to-fuel ratio. Further investigation is required to establish the appropriate trade-off limits for drying and energy recovery, considering different stool types, moisture content and drying characteristics. This is important for the design and further development of a self-sustained energy conversion and recovery systems for the NMT and similar sanitary solutions

    Sources of Airborne Endotoxins in Ambient Air and Exposure of Nearby Communities—A Review

    Get PDF
    Endotoxin is a bioaerosol component that is known to cause respiratory effects in exposed populations. To date, most research focused on occupational exposure, whilst much less is known about the impact of emissions from industrial operations on downwind endotoxin concentrations. A review of the literature was undertaken, identifying studies that reported endotoxin concentrations in both ambient environments and around sources with high endotoxin emissions. Ambient endotoxin concentrations in both rural and urban areas are generally below 10 endotoxin units (EU) m−3; however, around significant sources such as compost facilities, farms, and wastewater treatment plants, endotoxin concentrations regularly exceeded 100 EU m−3. However, this is affected by a range of factors including sampling approach, equipment, and duration. Reported downwind measurements of endotoxin demonstrate that endotoxin concentrations can remain above upwind concentrations. The evaluation of reported data is complicated due to a wide range of different parameters including sampling approaches, temperature, and site activity, demonstrating the need for a standardised methodology and improved guidance. Thorough characterisation of ambient endotoxin levels and modelling of endotoxin from pollution sources is needed to help inform future policy and support a robust health-based risk assessment process
    corecore